The wall receptacle will take care of the first 9 square feet, the next requirement for peninsula receptacles is for one to be installed within 2 feet of the end of the counter,, if 3 or more are required by the math, the "others" can be located according to the wishes of the design crew, homeowner or electrician. or even the general contractor.
The ceiling boxes will be required to be rated for fans per definition of Habitable rooms, 100 - Definition. The island will have receptacles per 210.52 (C)(2) lots of math needed. One receptacle for the first 9 sq ft, then one more for each 18 sq feet (OR FRACTION THEREOF).. 1 square in is a fraction thereof.. verify with your AHJ.
The receptacles for the countertops can be on the wall space or on the side of the cabinet or pop up receptacles that are rated for the counter top. several available. make sure they are listed for the location.